B-63324EN-1/03 OPERATION 9.SETTING AND DISPLAYING DATA
- 365 -
NOTE
1 Editing must not be performed for the group for
which life count operation is to be started with the
next M06 command, or for that group for which life
count operation is being performed. Otherwise, the
life management of the group is terminated forcibly.
2 When any of the following editing operations is
performed, the tool change signal may be set to 1:
- Tool skip setting for the last tool
- Tool number deletion from a tool group resulting
in the tool group containing only those tools
whose lives have expired, as well as skipped
tools
3 When any of the following editing operations is
performed, the tool change signal may be set to 0:
- Tool number addition to a tool group resulting in
the tools whose lives have not expired being set
in the tool group
- Setting for tool clearing
- Switching between pages
With the page keys
PAGE
PAGE
, the previous or following groups can be
displayed.
- Selecting a group
Method 1
(1) Press the [GROUP NUMBER] soft key.
(2) Enter a group number.
(3) Press the [EXEC] soft key.
Method 2
(1) Enter a group number.
(2) Press the [GROUP NUMBER] soft key.
- Switching between screens
Pressing the [SIGHT] soft key returns the screen display to the tool life
management directory screen.
- Setting of life count type, life values,
counter, and tool data
Method 1
(1) Press the [INPUT] soft key.
(2) Enter a number you want to set.
(3) Press the [EXEC] soft key.