1. DISPLAY AND OPERATION
B--63005EN/02
126
The active slave is subjected to the ZOOM function, which will be
described later, and parameter overwrite. The title of the active slave is
displayed in a color different from the display color of the other slave
titles.
The active slave can be selected by pressing the [↓NEXT] or [↑BACK]
soft key, which is displayed after the continuous menu key
is
pressed several times.
[↓NEXT]: Displays the screen of the Power Motion unit connected after
the currently active slave. The equipment other than the
Power Motion unit is ignored.
[↑BACK]: Displays the screen of the Power Motion unit connected
before the currently active slave.
Whether the screen displays the data of just a single unit or of four units
in four segments is specified in the SLV bit (bit 0 of parameter 960).
To switch the four--slave display to the single--slave display, press the
[ZOOM] soft key, which is displayed afterthe continuous menu key
is pressed several times. The single--slave display shows the data of the
active slave. To switch the single--slave display to the four--slave display
showing the data of four slaves including the active slave, press the
[ZOOM] key.
When five or more slaves are connected, the four--slave display has two
or more pages. To see the slave data that is not displayed on the current
page, press soft key [↓NEXT].
4.GROUP3 / ϒ
SYSTEM ****##
SERVO ****##
1.GROUP0 / ϒ O12345678 N12345
SYSTEM ****##
2.GROUP1 / ϒ
SYSTEM 88A101
POWER MOTION MANAGER/ SYSTEM CONFIGURATION O12345678 N12345
3.GROUP2 / ϒ
SYSTEM 88A101
PARAM DGNOS SYSTEM (OPRT)
The figure above shows a sample four--slave display screen on a display
unit with twelve soft keys. A unit with seven soft keys can also display
the four--slave display screen.
D Operating the active
slave
D Single--slave display/
Four--slave display