5110 IMPROPER G --CODE
(G05.1G1MODE)
(M series)
An illegal G code was specified in simple high--precision contour control
mode.
A command was specified for the index table indexing axis in simple
high--precision contour control mode.
5111 IMPROPER MODAL G--CODE
(G05.1 G1)
(M series)
An illegal G code is left modal when simple high --precision contour con-
trol mode was specified.
5112 G08 CAN NOT B E COMMANDED
(G05.1 G1)
(M series)
Look --ahead control (G08) was specified in simple high--precision con-
tour control mode.
5113 CAN NOT ERROR IN MDI MODE
(G05.1)
(M series)
Simple high--precision contour control (G05.1) was s pecified in MDI
mode.
5114 NOT STOP POSITION
(G05.1 Q1)
(M series)
At the time of restart after manual intervention, the coordinates at which
the manual interv ention occurred have not been restored.
5115 SPL : ERROR
There is an error in the specification of the rank.
(M series)
No knot is specified.
The knot specification has an error.
The number of axes exceeds the limits.
Other program errors
5116 SPL : ERROR
There is a program error in a block under look--ahead control.
(M series)
Monotone increasing of knots is not observed.
In NURBS interpolation mode, a mode that cannot be used together is
specified.
5117 SPL : ERROR
(M series)
The first contro l point of NURBS is incorre ct.
5118 SPL : ERROR
(M series)
After manual intervention with manual absolute mode set to on, NURBS
interpolation was restarted.
5122 ILLEGAL COMMAND IN SPIRAL
(M series)
A spiral interpolation or conical interpolation command has an error.
Specifically, this error is caused by one of the following:
1) L = 0 is specified.
2) Q = 0 is specified.
3) R/, R/, C is specified.
4) Zero is specified as height increment.
5) Three or more axes are specified as the height axes.
6) A height increment is specified when there are two height axes.
7) Conical interpolation is specified when the helical interpolation
function is not selected.
8) Q < 0 is specified when radius difference > 0.
9) Q > 0 is specified when radius difference < 0.
10) A height increment is specified when no height axis is specified.
5123 OVER TOLERANCE OF END POINT
(M series)
The difference between a specified end point and the calculated end
point exceeds the allowable range (parameter 3471).