5. INPUT AND OUTPUT OF DATA
B--63005EN/02
408
Operation for outputting data in a lump
(1) Connect external I/O device and set necessary parameters.
⋅ ChannelatNCside=0
⋅ Stop bit=2
⋅ Parity=No
⋅ Length of character=8
⋅ Baud rate=Depends on NC parameter no. 0103.
⋅ XON/OFF control=Yes
(2)Select EDIT mode. For path 2, select screen of tool post 1.
(3) Display basic menu screen, press [+] key to display the 2 nd page
soft keys.
(4)Press [17] to display the following data I/O menu screen.
[Data I/O menu Screen]
DATA I/O SCREEN
[ C A P : H E A D --- L ]
<
READ
I/O
SET UP
PUNCH
1. NC P ARAMETER (HD1)
2. NC OFFSET (HD1) 5. NC OFFSET (HD2) 8. CAP TOOL FILE
3. NC PROGRAM (HD1) 6. NC PROGRAM (HD2) 9. CAP PROGRAM
4. PMC PARAMETER
SINGLE
7. NC P ARAMETER (HD2)
SINGLE
CAUTION
For one--path control CNC, data select menu on tool post 2
is not displayed.
Output of conversutional
data in a lump