D M2 (connector number for pulse module 2)
For an axis that uses pulse module 2, enter a connector number using
a number in the range of between 1 and the maximum number of axes
for pulse module 2. When pulse module 2 need not be used, enter 0.
If a number that falls outside the valid range is entered, the warning
message “INVALID FORMAT” is displayed.
D TWO--AXES
Enter 1 for the following axes, each of which exclusively uses a DSP,
which is usually shared by two--axes. If a number other than 0 or 1 is
entered, the warning message “INVALID FORMAT” is displayed.
Learning control axis
High--speed current loop axis
High--speed interface axis
D Cs (Cs contour controlled axis)
Enter 1 for the Cs contour controlled axis. If a number other than 0
or 1 is entered, the warning message “INVALID FORMAT” is
displayed.
D TANDEM
Enter odd and even numbers for the master and slave axes for tandem
control. These numbers must be consecutive and in the range of
between 1 and 8. If a number that falls outside the valid range is
entered, the warning message “INVALID FORMAT” is displayed.
When soft key [SET] is pressed on the axis setting screen after data entry,
the warning message “SPECIFIED DATA IS OUT OF RANGE” is
displayed if any of the following conditions is satisfied.
D Both M1 and M2 are nonzero for an axis.
D Any two of TWO--AXES, Cs, and TANDEM are nonzero for an axis.
D A duplicate value is specified for M1.
D A duplicate value is specified for M2.
D A duplicate value is specified for Cs.
D A duplicate value is specified for TANDEM.
D An invalid master/slave axis pair is specified for TANDEM.