B--63005EN/02
1. DISPLAY AND OPERATION
59
045 C executor status
DGN
[Data type] Bit
[Valid data range] 0to255
C executor status
0: Normal.
2: Inoperable because of an incorrect FROM content.
3: Inoperable because the power was switched on with the M and 0 keys held
down.
5: Inoperable because of insufficient SRAM area; increase the SRAM area size.
Alternatively, inoperable because of an incorrect C executor library version; use
a new C executor library.
6: Inoperable because of an internal error.
7: Inoperable because of an internal error.
9: Inoperable because of an internal error.
10: Inoperable because of an incorrect C executor library version; use a new C
executor library .
11: Inoperable because of an incorrect FROM content.
12: Inoperable because of an internal error .
#7
OVL200
#6
LV
#5
OVC
#4
HCA
#3
HVA
#2
DCA
#1
FBA
#0
OFA
DGN
#7(OVL): Overload alarm
#6(LV): Insufficient voltage alarm
#5(OVC): Over current alarm
#4(HCA): Abnormal current alarm
#3(HVA): Overvoltage alarm
#2(DCA): Discharge alarm
#1(FBA): Disconnection alarm
#0(OFA): Overflow alarm
D C executor status
D Details of serial pulse
coder