B--63005EN/02
3. STAND--ALONE TYPE i SERIES HARDWARE
329
D Status LED display when an error occurs (green)
The status LEDs alternately display the LONG and SHORT patterns.
The LONG pattern is held longer than the SHORT pattern.
Status LED display
(STATUS)
o.
LONG
4321
SHORT
4321
t
ernet
oar
state
1 Jjjj jjjJ Reset exception
2 Jjjj jjJj General machine check exception
3 Jjjj jjJJ Data Storage
4 Jjjj jJjj Instruction Storage
5 Jjjj jJJj Alignment
6 Jjjj jJJJ Program
7 JjjJ jjjj Floating Point Unavailable
8 JjjJ jjjJ Decrementer
9 JjjJ jJjJ Trace
10 JjjJ jJJj Floating Point Assist
11 JjJj jjjj Implementation Dependent Software Emulation
12 JjJj jjjJ Implementation Dependent Instruction TLB Miss
13 JjJj jjJj Implementation Dependent Data TLB Miss
14 JjJj jjJJ Implementation Dependent Instruction TLB Error
15 JjJj jJjj Implementation Dependent Data TLB Error
16 JjJJ jJjj Implementation Dependent Data Breakpoint
17 JjJJ jJjJ Implementation Dependent Instruction Breakpoint
18 JjJJ jJJj Implementation Dependent Peripheral Breakpoint
19 JjJJ jJJJ Implementation Dependent Non Maskable Develop-
ment
20 JJjj jjjJ DRAM Parity Alarm
21 JJjj jjJj Other NMI
22 JJJj jjjJ Invalid interrupt
NOTE
If any of the errors occurs, contact FANUC.