1. DISPLAY AND OPERATION
B--63005EN/02
36
Mode selection signals and rapid traverse override signals
are displayed as indicated below:
Input signal
MD1 ND2 MD4 REF DNC1
0 0 0 0 0 MDI
1 0 0 0 0 MEM
1 0 0 0 1 RMT
0 1 0 0 0 NOMODE
1 1 0 0 0 EDT
0 0 1 0 0 H/INC
1 0 1 0 0 JOG
1 0 1 1 0 REF
0 1 1 0 0 TJOG
1 1 1 0 0 THND
Input signal
ROV1 ROV2
0 0 R100%
1 0 R50%
0 1 R25%
1 1 RF0%
(3) NC alarms
NC alarms are displayed in reverse video.
P/S alarms, system alarms, and external alarms are displayed together
with their numbers.
For other types of alarms, only the alarm type is displayed. (No details
are displayed.)
For two--path control, the operations of path 2 are displayed in the
same way, but preceded by S_.
Example)
P/S0050, SV_ALM, S_APC_ALM
(4)Time stamp (date and time)
The following time data (date and time) is recorded:
1) Date and time of power--on
2) Date and time of power--off
3) Date and time when an NC alarm occurs
4) The clock time is recorded at predetermined intervals, together
with each new calendar day.