B-63944EN-2/02 PROGRAMMING 5.FUNCTIONS TO SIMPLIFY PROGRAMMING
- 83 -
- Reset
When a reset is performed during rigid tapping, the rigid tapping
mode is canceled and the spindle motor enters the normal mode.
Note that the G84 (G74) mode is not canceled in this case when bit 6
(CLR) of parameter No. 3402 is set.
- Interlock
Interlock can also be applied in G84 (G74).
- Feed hold and single block
When bit 6 (FHD) of parameter No. 5200 is set to 0, feed hold and
single block are invalid in the G84 (G74) mode. When this bit is set
to 1, they are valid.
- Manual feed
For rigid tapping by manual handle feed, see the section "Rigid
Tapping by Manual Handle."
With other manual operations, rigid tapping cannot be performed.
- Backlash compensation
In the rigid tapping mode, backlash compensation is applied to
compensate the lost motion when the spindle rotates clockwise or
counterclockwise. Set the amount of backlash in parameters Nos.
5321 to 5324.
Along the drilling axis, backlash compensation has been applied.
Limitation
- Axis switching
Before the drilling axis can be changed, the canned cycle must be
canceled. If the drilling axis is changed in rigid mode, alarm PS0206
is issued.
- S command
• Specifying a rotation speed exceeding the maximum speed for the
gear used causes alarm PS0200.
• When the rigid tapping canned cycle is cancelled, the S command
used for rigid tapping is cleared to S0.
- Distribution amount for the spindle
The maximum distribution amount is as follows (displayed on
diagnostic screen No. 451):
• For a serial spindle: 32,767 pulses per 8 ms
This amount is changed according to the gear ratio setting for the
position coder or rigid tapping command. If a setting is made to
exceed the upper limit, alarm PS0202 is issued.
- F command
Specifying a value that exceeds the upper limit of cutting feedrate
causes alarm PS0011.