B-64663EN/01 LASER FUNCTION 6.TRACING CONTROL
- 91 -
6.1.2 Tracing Control Adjustment
Overview
After connecting the signal from the sensor to the CNC, make the
adjustments described below.
Sensor adjustment
Position the sensor so that the distance between the sensor and
workpiece is equal to the sensor stroke + α (standard value: 2 mm +
α). (α is between about 0.1 mm and 0.2 mm.)
At this position, adjust the zero point of the sensor amplifier so that
the sensor outputs a sense signal of about 0 V.
Move the sensor toward the workpiece by an amount equal to the
positive stroke (standard value: 2 mm) of the sensor, then adjust the
sensor amplifier so that the sensor outputs a sense signal of +10 V.
Similarly, move the sensor away from the workpiece by an amount
equal to negative stroke (standard value: -2 mm) of the sensor, then
adjust the sensor amplifier so that the sensor outputs a sense signal of
-10 V.
Sensor adjustment on the CNC
Select a sensing stroke by specifying parameter No. 15504. If the
sense signal polarity of the sensor is inverted, set bit 0 (TIV) of
parameter No. 15503 to 1.
Sensing gain setting
Set a sensing gain coefficient with the trace setting screen.
Repeat the following operation a few times to check that there is no
significant setting variation (within about ±20).
Select the trace setting
screen.
Move the nozzle towards the
workpiece using manual operation.
Press soft key [START
POINT].
Move the nozzle about 1mm
towards the workpiece using a
og or handle feed.
Press soft key [END POINT].
Setting is
complete.
Is the
displayed shift starting
change?
NO
YES