B-64663EN/01 LASER FUNCTION 2.FUNCTIONS DIFFERING FROM THE M SERIES SPECIFICATIONS
- 41 -
2.3.3 Single Block
Difference
When a beam output command block is executed and terminated, feed
stops, the beam is turned off, the shutter is closed, and none of the
assist gas select signals (AG1 to AG3) is selected.
When the automatic operation start signal (ST) is set to 1, then to 0
again, execution of the next block starts.
If this block specifies beam output, the assist gas select signals (AG1
to AG3) are placed in the state existing before the single block stop
occurred. The shutter is opened, the beam is turned on, and machine
movement starts.