B-64663EN/01 LASER FUNCTION 4.ASSIST GAS
- 61 -
When a flow pattern is specified
If the gas flow pattern data is set in the gas flow field of the laser
setting screen, assist gas control is performed as described below:
G32 P_ Q_; (non-zero values for P and Q) starts assist gas
control, causing the specified pressure to be output during the
specified period, as the previous step. When the specified period
elapses, the machining pressure is output, rather than the pressure
in the previous step. The machining pressure signal (WKP) is set
to 1.
When G32 P0; is specified, the pressure specified for the
subsequent step is output, instead of the machining pressure, and
the machining pressure signal (WKP) is reset to 0.
Once the period for the subsequent step elapses, the pressure is
reduced to 0.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G221 AGRDY
G222 AGST
F220 WKP AGSLT
F222 AG3 AG2 AG1
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
15001 LHC EXA
[Data type] Bit
EXA The assist gas select signals offer a choice of:
0: Three types. (normal)
1: Seven types. (code output)