B-64663EN/01 LASER FUNCTION 5.LASER OUTPUT CONTROL
- 85 -
5.6.5 Laser Oscillator Not Connected Signal
Overview
This signal is output if no laser oscillator is connected.
Signal
- Laser oscillator not connected signal
LONC<F223#7>
[Classification] Output signal
[Function] Notifies the PMC that no laser oscillator is connected to the CNC.
[Output condition] The signal is set to "1" if the power is turned on with no laser
oscillator connected.
CAUTION
This signal is output if the system determines that
no laser oscillator is connected when the power is
turned on. The state of the signal does not,
therefore, change if a laser oscillator is connected
or disconnected after the power is turned on.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
F223 LONC