B-64663EN/01 LASER FUNCTION 6.TRACING CONTROL
- 101 -
15537 Tracing range-over alarm (E
OVRS
)
[Data type] Word
[Unit of data] 0.001mm
[Valid data range] 0 to 32767
[Standard setting value] 1000
When the absolute value of a tracing shift exceeds the value set in this
parameter, an alarm, or a signal indicating that the value set in this
parameter has been exceeded, is output.
15538 Tracing range-over alarm mask
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
[Standard setting value] 1000
When the standard shift is rewritten during tracing, the tracing
range-over alarm is detected in the transient state. In this case, tracing
range-over alarm detection is masked for the period set in this
parameter.
15539 Tracing range-over alarm offset (E
OVRD
)
[Data type] Word
[Unit of data] 0.001mm
[Valid data range] 0 to 32767
[Standard setting value] 0
An offset for the value set in parameter No. 15537 can be added to an
approach
side sense value. As a result, the sensing range is:
-E
OVRS
≥ ∆E, ∆E ≥ E
OVRS
+ E
OVRD