B-64663EN/01 LASER FUNCTION 8.CONTROL FUNCTION
- 221 -
8.10 PULSE ENHANCED FUNCTION
Overview
If an overridden value of output power Pc exceeds a predetermined
value (parameter No. 15213), the pulse duty ratio is limited to 50% or
less.
The overridden value of output power Pc is limited to a predetermined
value (parameter No. 15210).
If the duty ratio is limited to 50%, the power value obtained after
power compensation and power feedback addition is limited to the
setting made with parameter No. 15207. If the duty ratio is not limited
to 50%, the power value is limited to the setting made with parameter
No. 15212.
Parameter
15212 Maximum power when the pulse duty ratio is not limited
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
When the pulse duty ratio is not limited to 50% according to the
setting made with parameter No. 15213, the power value obtained
after power compensation and power feedback addition cannot exceed
this value.
15213 Criterion for clamping the duty ratio
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
If an overridden value of the power Pc exceeds this setting, the pulse
duty ratio is limited to 50% or less, and the power value is limited to
the setting made with parameter No. 15210.
NOTE
When this function is not used, set identical values
in parameters No. 15210 and No. 15213 and in
parameters No. 15207 and No. 15212.