B-64663EN/01 LASER FUNCTION 4.ASSIST GAS
- 63 -
4.2 ASSIST GAS PRESSURE ANALOG OUTPUT
Overview
When assist gas control is specified, the CNC outputs the specified
assist gas pressure as an analog voltage signal. As the destination of
the signal, either the analog spindle interface on the main board or the
analog output on the analog option board can be selected.
Which to use can be specified with bit 4 of parameter No. 15011.
For details of how to connect the voltage signal, see the explanation of
the hardware.
The relationship between the specified assist gas pressure and the
voltage level of an analog output signal can be specified in parameter
No.15132.
Upon receiving the assist gas pressure analog output signal from the
CNC, the assist gas control unit should operate the control valve and
automatically adjust the assist gas pressure.
When the control valve operation contains a delay time that cannot be
ignored, the CNC operation can be delayed by adjusting the gas
pressure setting time or pre-flow time.
- When gas pressure control is to be specified directly, adjust the
gas pressure setting time.
- When a flow pattern is specified, adjust the pre-flow time.