B-64663EN/01 LASER FUNCTION 8.CONTROL FUNCTION
- 233 -
Parameter
- Parameters related to linear acceleration/ deceleration before interpolation
1770
Maximum cutting speed during linear acceleration/deceleration before
interpolation
[Data type] 2-word
[Unit of data]
Valid data range
[Valid data range]
Input increment Unit of data
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 240000 6 to 100000
Inch machine 0.1 inch/min 6 to 9600 6 to 4800
Specify the maximum cutting speed during linear acceleration/
deceleration before interpolation.
(Parameter 1 for specifying the acceleration of linear acceleration/
deceleration before interpolation)
1771
Time required to reach the maximum cutting speed during linear
acceleration/deceleration before interpolation (time constant)
[Data type] Word
[Unit of data] 1 msec
[Valid data range] 0 to 4000
Specify the time (time constant) required to reach the speed specified
in parameter 1.
(Parameter 2 for specifying the acceleration of linear acceleration/
deceleration before interpolation)
NOTE
1 If either parameter No. 1770 or 1771 is set to 0, no
linear acceleration/deceleration before interpolation
is applied.
2 The setting of parameter No. 1770 divided by the
setting of parameter No. 1771 must be equal to or
greater than 5.
Speed
(mm/min)
Time (msec) Parameter No. 1771
Parameter
No. 1770
1784
Speed assumed when an overtravel alarm is raised during linear
acceleration/deceleration before interpolation
[Data type] Word
[Unit of data]
Valid data range
[Valid data range]
Input increment Unit of data
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800