6.TRACING CONTROL LASER FUNCTION B-64663EN/01
- 100 -
- Trace check mode signal
TRCKM<G225#2>
[Classification] Input signal
[Function] This signal detects whether the tracing shift exceeds a specified
tracing range-over alarm value.
[Operation] (1) When the trace check mode signal (TRCKM) is set to 0
When the tracing shift exceeds a tracing range-over alarm value
(set in parameter No. 15537), tracing is stopped, and the alarm
signal (TRALM) is set to 1.
(2) When the trace check mode signal (TRCKM) is set to 1
While the tracing shift exceeds the tracing range-over alarm
value (set in parameter No. 15537), the tracing disabled state
signal (TRERS) is set to 1.
- Tracing disabled state signal
TRERS<F220#0>
[Classification] Output signal
[Function] This signal informs the PMC that the tracing shift exceeds the
specified tracing range-over alarm value.
[Output condition] This signal is set to 1 in the following case:
- When the trace check mode signal is set to 1, and the tracing shift
exceeds the tracing range-over alarm value (set in parameter No.
15537)
This signal is set to 0 in the following cases:
- When the trace check mode signal is set to 0
- When the trace check mode signal is set to 1, and the tracing shift
is within the tracing range-over alarm value (set in parameter No.
15537)
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G225 TRCKM
F220 TRALM TRERS
Parameter
15533 Tracing over-shift alarm
[Data type] Word
[Unit of data] 0.001mm
[Valid data range] 0 to 32767
[Standard setting value] 1200
If the tracing shift exceeds the tracing over-shift alarm value, set in
this parameter, an alarm is issued and operation is stopped, with the
occurrence of an abnormal approach assumed.