8.CONTROL FUNCTION LASER FUNCTION B-64663EN/01
- 214 -
8.8 LASER GAS MIXER FUNCTION
Overview
When a mixed laser gas is not available, the laser gas mixer function
is used to create a laser gas by mixing nitrogen, helium, and CO
2
gases
in a predetermined proportion. A special laser gas mixer is necessary.
For details, read the manual provided with the laser gas mixer.
Mixture sequence
See the flowchart below.
(1) When the mixer is not connected, the conventional sequence is
used.
(2) RUN-ON starts the mixer operation.
(3) Check the levels of the CO
2
-gas, helium, and nitrogen cylinders.
If any level is too low, 111 is displayed on the diagnostic screen
(No. 987).
(4) The tank is evacuated if the previous operation stopped while the
tank was being supplied with gases. Otherwise, this step is
skipped.
(5) The previous operation stop status is checked. According to the
status, the gas supply is started. When the low-order bits of
parameter No. 15009 are 0000, tank A is supplied with gases,
mixes those gases, then starts supplying the mixed gas.
(6) After the mixed gas supply starts, the laser oscillator sequence
starts.
(7) If the previous operation was stopped while the tank was
preparing to supply gas, the gas supply starts immediately.
(8) First, the cylinder levels are checked. If any cylinder level is too
low, 111 is displayed on the diagnostic screen (No. 987). The
sequence remains stopped until the cylinder is replaced. When
the BCAN signal (G221#5) is set to 1 after the cylinder is
replaced, the gas supply starts. The tank in which the gas level is
low is supplied with the gases in a predetermined proportion.
(9) After the tank is filled with the gases, a wait time (of about 1
hour) is necessary to ensure a uniform mixture. Then, the tank is
switched.
(10) The gas level of the mixed gas tank is checked.
(11) If the gas level of the mixed gas tank is low, the tank is switched
to another tank.
(12) RUN-OFF stops the mixer. POWER-OFF should not be done
until the gas supply is completed. POWER-OFF during gas
supply may result in the gases being mixed in the wrong
proportion.