5.LASER OUTPUT CONTROL LASER FUNCTION B-64663EN/01
- 68 -
Signal
- Shutter lock signal
*SHTLC<G222#0>
[Classification] Input signal
[Function] Interlocks the shutter open/close command so that the shutter will not
open.
[Operation] Set the shutter lock signal (*SHTLC) to 0 to prevent the shutter from
being opened or closed by an invalid shutter open/close command.
To open or close the shutter with the shutter open/close command,
first set the shutter lock signal (*SHTLC) to 1.
- Shutter open signal
SHTON<G222#3>
[Classification] Input signal
[Function] Opens and closes the shutter.
[Operation] When bit 6 (LHC) of parameter No.15001 is set to 0 and the shutter
lock signal (*SHTLC) is set to 1, setting the shutter open signal
(SHTON) to 1 in manual operation mode opens the shutter.
- Shutter ON/OFF signal
SHTONL,SHTOFL<F220#4,F220#3>
[Classification] Output signal
[Function] Notifies the PMC whether the oscillator shutter is open or closed.
[Output condition] The SHTONL and SHTOFL signals indicate whether the shutter is open
or closed. The relationship between the shutter statuses and signal
statuses is indicated below. The PMC should judge the shutter status
from both the SHTONL and SHTOFL signals.
The shutter transient state generally lasts for 500 to 600 msec. If the
transient state continues for one second or longer, it indicates that the
shutter has not opened or closed normally.
Signal
State of the shutter
SHTONL SHTOFL
Shutter open 1 0
Shutter closed 0 1
1 1
Shutter transient state
0 0
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G222 SHTON *SHTLC
F220 SHTONL SHTOFL