7.THREE-DIMENSIONAL MACHINING SYSTEM LASER FUNCTION B-64663EN/01
- 120 -
Signal
- Attitude control B speed clamp select signal
OTPMX2<G224#7>
[Classification] Input signal
[Function] Allows selection between maximum feedrate parameters for the
automatic feedrate override function in attitude control B.
[Operation] When the signal (OTPMX2) is set to 0, parameter No. 15621 takes
effect.
When the signal (OTPMX2) is set to 1, parameter No. 15622 takes
effect.
- Attitude control mode select signal
ALNAXS<G226#2>
[Classification] Input signal
[Function] Selects whether the nozzle is operated in nozzle head fixing mode or
independent axis mode, during manual operation.
[Operation] When the attitude control mode select signal (ALNAXS) is set to 0,
the nozzle is operated in nozzle head fixing mode.
When the attitude control mode select signal (ALNAXS) is set to 1,
the nozzle is operated in independent axis mode.
Manual reference position return is always performed in independent
axis mode, regardless of the state of the mode select signal. Attitude
control is enabled once reference position return has been completed.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G224 OTPMX2
G226 ALNAXS
Parameter
1020 Axis names used in the program
[Data type] Byte axis
Select the names of the 4th and 5th axes from A, B, C, U, and V, and
set the relevant values. When W-axis tracing is selected, select W as
the name of the 6th axis.
Axis name Setting value Axis name Setting value
A 65 U 85
B 66 V 86
C 67 W 87