B-64663EN/01 LASER FUNCTION 8.CONTROL FUNCTION
- 173 -
Data group items
- Piercing data group
Piercing data items are provided for the high-speed piercing function
as described below.
To specify an ordinary piercing function, specify 0 for the step count.
In this case, piercing is performed based on the peak value, initial
frequency, initial duty cycle, and piercing time. See the chapter for the
high-speed piercing function for how high-speed piercing is
performed.
(1) The piercing data group consists of the items listed below.
Item Setting range Setting unit
Peak value
Initial frequency
Initial duty cycle
Frequency increment
Duty cycle increment
Step time
Step count
Piercing time
Assist gas pressure
Assist gas type
Assist gas setting time
Standard shift
0 to 9999
5 to 2000
0 to 100
0 to 2000
0 to 99
0 to 9.999
0 to 99
0001 to 999.999
0 to 2.55
1 to 7
0 to 9.9
-9.999 to 9.999
W
Hz
%
Hz
%
s
Cycle
s
MPa
Type
s
mm
(2) Capacity
Three sets of the above items constitute a group.
(3) Calling method
If the program specifies a piercing data set number (101 to 103)
after address E, the data set corresponding to the specified
number is read as active data.
Exxx ;
Piercing data set number (101 to 103)
- Machining data group
(1) The machining data group consists of the items listed below.
Item Setting range Setting unit
Feedrate
Contouring peak value
Contouring frequency
Contouring duty cycle
Assist gas pressure
Assist gas type
Assist gas setting time
Standard shift
Beam diameter correction amount
Edge machining selection
Start-up selection
0 to 99999
0 to 9999
5 to 2000
0 to 100
0 to 2.55
1 to 7
0 to 9.9
-9.999 to 9.999
-9.999 to 9.999
0/201 to 205
0/201 to 205
mm/min
W
Hz
%
MPa
Type
s
mm
mm
Auxiliary data number