3.LASER SEQUENCE CONTROL LASER FUNCTION B-64663EN/01
- 50 -
Stopping the oscillator
When the oscillator start signal (RUN) is set to 0 during
operation, if discharge is being performed, the CNC stops
discharge. If discharge is not being performed, the CNC
immediately closes the laser gas supply valve, and opens the
exhaust valve to evacuate the fan system for the period specified
in parameter No.15256.
At this time, the discharge start ready signal (LRDY) is set to 0,
and the oscillator ready signal (WAIT) is set to 1.
Upon the completion of evacuation, the CNC starts purge
processing to supply new laser gas, up to atmospheric pressure.
Once purge processing has been completed, the oscillator ready
signal (WAIT) is set to 0, and the purge completion signal
(PURGE) is set to 1.
For the Y series oscillator, the laser gas is not controlled. Hence,
evacuation is not performed.
CAUTION
Safety standards for laser application devices (e.g.,
FDA Part 1040 PERFORMANCE STANDARDS
FOR LIGHTEMITTING PRODUCTS, Sec 1040.10
Laser Products, (f), (4) Key control) specify that a
key switch shall be used as the start and stop
switch of an oscillator and that it shall not be
possible to remove the key during operation of the
oscillator.
To maintain compliance with these safety
standards, always use a key switch as the
oscillator start signal (RUN) switch.
- Oscillator ready signal
WAIT<F221#3>
[Classification] Output signal
[Function] This signal notifies the PMC that oscillator start processing or stop
processing is being performed.
[Output] The signal becomes 1 under the following conditions:
- When the oscillator start signal (RUN) is set to 1 while the purge
completion signal (PURGE) is set to 1
- When the oscillator start signal (RUN) is set to 0 while the
discharge start ready signal (LRDY) is set to 1
The signal becomes 0 under the following conditions:
- When the CNC is ready for discharge in the oscillator start
sequence
- When purge processing has been completed in the oscillator stop
sequence