5.LASER OUTPUT CONTROL LASER FUNCTION B-64663EN/01
- 74 -
5.3 OUTPUT OVERRIDE
5.3.1 Power Override Signal
Overview
When the C-series or Y-series oscillator is being used, the currently
set output power can be overridden. The override value can be
specified within a range of 0% to 200%, in units of 1%.
Signal
- Power override signals
POV0 to POV7<G223#0 to #7>
[Classification] Input signal
[Function] Overrides the currently set output power.
[Operation] When the C-series or Y-series oscillator is being used, the currently
set output power can be overridden. The override value can be
specified within a range of 0% to 200%, in units of 1%.
If the overridden power falls outside the range specified for the system,
it is rounded up or down to the upper or lower limit of the range.
Signal Override
%
POV7 POV6 POV5 POV4 POV3 POV2 POV6 POV0
0 0 0 0 0 0 0 0 0
1 0 0 0 0 0 0 0 1
: : : : : : : : :
100 0 1 1 0 0 1 0 0
: : : : : : : : :
200 1 1 0 0 1 0 0 0
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G223 POV7 POV6 POV5 POV4 POV3 POV2 POV1 POV0
NOTE
During high-speed piercing, this function is
disabled.