B-64663EN/01 LASER FUNCTION 8.CONTROL FUNCTION
- 171 -
15704 U-axis reference position compensation value
[Data type] Word
[Unit of data] mm
[Valid data range] -32767 to 32767
[Standard setting value] 0
This value is specified as a distance from the reference position so that
the position of the mirror block axis (U-axis) is compensated to obtain
the optimum propagation distance
15705 Optical path length compensation coefficient
[Data type] Word
[Unit of data] 1/64
[Valid data range] 64 to 32767
[Standard setting value] 128
The result of adjusting the total movement of the axes specified in
parameter No. 15700 with this coefficient is used as a move command
for the U-axis.
Alarm and message
No. Message Contents
4056 OPT. PATH NOT SET The mirror block position cannot be
corrected. The position of the U-axis
(mirror block move axis) cannot be
calculated from the current position of any
axis. Perform reference position return.