8.CONTROL FUNCTION LASER FUNCTION B-64663EN/01
- 170 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
15700 8 7 6 5 4 Z Y X
[Data type] Bit
X to 8 0: Axis on which the length of the optical path changes (used as a
basis for calculation of the U-axis move command)
1: Axis on which the length of the optical path does not change (not
used as a basis for calculation of the U-axis move command)
CAUTION
Specify 0 for non-existing axes.
#7 #6 #5 #4 #3 #2 #1 #0
15701 8 7 6 5 4 Z Y X
[Data type] Bit
X to 8 0: Does not invert the polarity of the calculated move amount for
the axis.
1: Inverts the polarity of the calculated move amount for the axis.
CAUTION
Specify 0 for non-existing axes.
#7 #6 #5 #4 #3 #2 #1 #0
15702 MRO MCO FMS TXC
[Data type] Bit
TXC 0: Specifies to include the move amount of a controlled axis under
tracing control in the move command calculation for the U-axis.
1: Specifies not to include the move amount of a controlled axis
under tracing control in the move command calculation for the
U-axis.
FMS 0: Specifies to enable optical path length compensation.
1: Specifies to disable optical path length compensation.
MCO The sign of the compensation amount for the reference position of the
axis of mirror movement is:
0: Plus.
1: Minus.
MRO The optical path length compensation stop request signal is set to 1
when:
0: An overtravel occurs on the mirror block axis.
1: An overtravel occurs on the mirror block axis and the axis
specified in parameter No. 15700.
15703 MIRAXS
[Data type] Byte
[Unit of data]
[Valid data range] 4 to 8
Selects which axis to be used as the U-axis along which the mirror
block moves.