B-64663EN/01 LASER FUNCTION 8.CONTROL FUNCTION
- 205 -
15671 High-speed piercing initial frequency
[Data type] Word
[Unit of data] Hz
[Valid data range] 5 to 2000
Specify the initial frequency for high-speed piercing to be used during
a skip.
15672 High-speed piercing frequency increment
[Data type] Word
[Unit of data] Hz
[Valid data range] 0 to 2000
Specify the frequency increment for high-speed piercing to be used
during a skip.
15673 High-speed piercing initial duty cycle
[Data type] Word
[Unit of data] %
[Valid data range] 0 to 100
Specify the initial duty cycle for high-speed piercing to be used during
a skip.
15674 High-speed piercing duty cycle increment
[Data type] Word
[Unit of data] %
[Valid data range] 0 to 100
Specify the duty cycle increment for high-speed piercing to be used
during a skip.
15675 High-speed piercing step time
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
Specify the step time for high-speed piercing to be used during a skip.
15676 High-speed piercing step count
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
Specify the step count for high-speed piercing to be used during a
skip.
15677 High-speed piercing end time
[Data type] 2-word
[Unit of data] msec
[Valid data range] 0 to 99999999
Specify the end time for high-speed piercing to be used during a skip.