15.
CLJSTOM
MACRO
15.5
External Output Commands
(5)
(
1
a
w
(
)
C
(d)
(
)
0
After the
data is output by
ISO,
it is
S8l8Ct8d
whether only ‘LF” is output or
“LF”
and
“CR” are output.
piiq
I
NCR
7
6 5
4
3
2
1
0
NCR 1:
“LF
“and
“CR”
are output after the data is output.
0:
Only “LF” is output after the data is output.
Cautions
It is not necessary to sequentially specify open command
(POPEN),
data output
commands (BPRNT, DPRNT) and close command (PCLOS). When
th8
open
command is specified at the start of a program, it is no longer necessary to
specify the open command again until
after
the close command is specified.
Specify the open command and close command as a pair of commands without
fail.
In other words, send the close command at the end of a program. Don’t
specify the close command
ind8p8nd8ntly
without the open command.
A data output command in progress is stopped and subsequent data are
erased
by reset processing.
Accordingly, if reset processing is
Specified
by M30, or the like, at the end of a
data output program, specify the close command at the end of the program and
wait until all data are output before starting M30 processing or other reset
processing.
If a macro word is specified in
[ ]
by abbreviation, it remains abbreviation.
How8v8r,
if the characters in
[
]
are input in two or more phrases, an
abbreviation of the second phrase or later is converted and input.
yOm
is also input in
[
1.
However, if two or more
“0”
is input, it will be omitted at the second time or
later.
i-im