11. SE’TTING AND DISPLAYING DATA
11.5 Pitch Error Compensation Data
11.5 Pitch Error Compensation Data
If pitch error compensation data is specified for parameters 3620 to 3624,pitch errors
of each axis can be compensated in detection unit per axis.
The pitch error compensation data is set according to the characteristics of the
machine connected to the NC. The content of this data varies according to the
machine model. If it is changed, the machine accuracy is reduced.
In principle, the end user must not alter this data.
When the position after returning to the reference position is the compensation home
position, set the amount to be compensated for the specified number of compensation
points at each compensation interval specified for each axis.
To assign the compensation points for each axis, specify the positive direction or the
negative direction in reference to the compensation point No. of the reference position.
If the machine stroke exceeds the specified range on either the positive direction or
the negative direction, the pitch error compensation does not apply beyond the range.
(a)
(b)
( 1
C
(d)
Number of compensation points
Per axis: 0 to 1024 points, but the total number of points for all axes must not
exceed 1024.
Compensation point No.:
0 to 1023 (common to all axes)
Range of amount of compensation
Per compensation point:
( - 7) - ( + 7) X compensation magnification (Detection
unit)
Compensation magnification: 0 to 100 (to be specified for each axis)
Interval between pitch error compensation points
0 to 99999999 (Increment system)
The following limit applies to the interval between the pitch error compensation
points:
Compensation interval ) Maximum feedrate (normally, quick traverse)/7500
Units in the above expression are mm, inches, and deg for the interval and
mm/min, inchesimin, deg/min for the feedrate.
(Example)
If the maximum feedrate is 15000 mm/min, the interval between the
pitch error compensation points is 2 mm or more.
When the set value is 0, no compensation is performed.
Pitch error compensation of the rotating axis
For the rotating axis, the interval between the pitch error compensation points
shall be set to one per integer of the amount of movement (normally 360°) for
each rotation.
The sum of all pitch error compensation amounts per rotation must be made to
.
0
Note that the pitch error is not compensated in the following cases:
0
i
(ii)
(iii)
When the machine is not returned to the reference position after turning on
the power. This excludes the case where an absolute position detector is
employed.
If the interval between the pitch error compensation points is 0.
If the compensation point Nos. on the positive or negative direction do not
fall within the range of 0 to 1023.
2-84