20. PMC PROGRAMMER (DPVMDI)
._
20.2 Setting and Displaying of SYSTEM PARAMETER (SYSTEM PARAM)
When System parameter (SYSTEM PARAM) is selected on PMC programmer menu,
enabling the System parameter screen to be displayed.
When this function is selected, if the sequence program is in operation, it
automatically stops.
(3)
(4
( )
a
(b)
(5)
Display the PMC programmer menu.
Display the SYSTEM PARAM item by pressing c 4 > key or C f > key.
~1 _
System parameter screen is displayed by pressing < INPUT> key or
< READ > key.
>I
Current counter data type is displayed.
This parameter specifies whether the format of a counter value used with the
CTR function instruction is to be binary or BCD. (binary --) CO> or BCD +
a>) .
Press <INPUT> key.
The display returns to the PMC programmer menu by pressing c CAN ) key or
<WRITE > key.
20.3 Editing Sequence Program (EDIT)
Select Editing Sequence program (EDIT) from the PMC programmer menu. Editing
menu is displayed.
0
Display the PMC programmer menu.
.
(2)
Press < 1 > key or < t ) key. The EDIT item appears.
(3)
Press c INPUT > key or < READ) key. PMC editing menu appears.
PMC EDIT
>LADDER
l/l
The display returns to the PMC programmer menu by pressing <CAN ) key or
c WRITE ) key.