A-78640E
Sheet
Title
Draw
No.
04 Feb.08.’03 Part of (4) is added or modified. Addition of 2.16.5
03 Jul.02.’02 A. Fukumoto Part of (3) is added or modified. T.Endo
02 May.13.’02 A. Fukumoto Addition of Tool Radius control for 5-axis machining etc T.Endo
Ed. Date Design Description
Date Jan.25.’02 Desig. A.Fukumoto Apprv. T.Endo
FANUC Series 16i /18i -TB
Specifications of AI High-Precision Contour Control /
I Nano High-Precision Contour control
183/190
• Workpiece coordinate system preset -G50.3 [G92.1]
• Local coordinate system setting -G52
• Machine coordinate system setting -G53
• Single direction positioning -G60
• Automatic corner override -G62
• Cutting mode -G64
• Macro call -G65, G66, G67, G66.1
(The subprogram call is
possible.)
• Three dimensional coordinate conversion -G68.1/G69.1
• Multiple repetitive cycle* -G70∼G76 [G72∼G78]
• Canned grinding cycle* -G71∼G74 [G72∼G78]
• Canned cycle for drilling* -G80∼G89
• Hobbing machine function* -G80.4∼G84.4
• Canned cycle* -G90 [G77,G20],G92[G78,G21],
G94 [G79,G24]
• Constant surface speed control -G96, G97
• Per revolution feed * -G99 [G95]
• Tool offset -T code
6.2 Notes on Operation
• Interlock
The interlock signal for each axis and direction is not effective in AI HPCC / AI
NANO HPCC operation.
• Each axis machine lock, mirror image and inch/metric conversion
The mirror image by the signal, the mirror image by the setting, the each axis
machine lock, and inch/metric conversion (G20/G21) are not operated
immediately if they changed in AI HPCC / AI NANO HPCC mode. Please switch
them before AI HPCC / AI NANO HPCC is turned on.
• Pocket calculator type decimal point input
Pocket calculator type decimal point input (parameter No.3401#0(DPI)) is not
effective in AI HPCC / AI NANO HPCC operation.
• Automatic corner override
An automatic corner override are invalid in AI HPCC / AI NANO HPCC
operation.
• MDI operation
It is not possible to operate by switching to the MDI mode in AI HPCC / AI
NANO HPCC mode. The edit of the MDI operation is prohibited in AI HPCC / AI
NANO HPCC mode. Moreover, P/S010 alarm occurs if cycle-start is applied
without inputting the program.
Moreover, it is not possible to instruct in a AI HPCC / AI NANO HPCC in the
MDI mode.(P/S alarm 010 occurs.)