snx: UINT, variable or constant; the index into the source array.
dnx: UINT, variable or constant; the index into the destination array.
n: UINT, variable or constant; count indicator.
ds: WORD variable; the first element of the destination array.
length: Constant; the number (1 - 32767) of elements (starting at 'sr' and 'ds') that make up each array.
4.7.1.7 ARRAY_MOVE_DWORD( sr, snx, dnx, n, length, ds)
When the function receives power flow, the number of data elements in the count indicator 'n' is extracted from the
input array starting with the indexed location ('sr' + 'snx' – 1). The data elements are written to the output array starting
with the indexed location ('ds' + 'dnx' – 1).
sr: DWORD variable; the first element of the source array.
snx: UINT, variable or constant; the index into the source array.
dnx: UINT, variable or constant; the index into the destination array.
n: UINT, variable or constant; count indicator.
ds: DWORD variable; the first element of the destination array.
length: Constant; the number (1 - 32767) of elements (starting at 'sr' and 'ds') that make up each array.
For more details, see LD Functions.
Note: IL and LD functions are generally the same, with some differences in data types for operands.