OPERATION
2. OPERATIONAL DEVICES
B–63444EN/01
226
Before an external input/output device can be used, parameters must be
set as follows.
Power Mate
MAIN CPU BOARD
Channel 1
JD5A
RS–232–C
Reader/
puncher
Power Mate has one channels of reader/punch interfaces. The
input/output device to be used is specified by setting the channel
connected to that device in setting parameter I/O CHANNEL.
The specified data, such as a baud rate and the number of stop bits, of an
input/output device connected to a specific channel must be set in
parameters for that channel in advance.
For channel 1, two combinations of parameters to specify the input/output
device data are provided.
The following shows the interrelation between the reader/punch interface
parameters for the channels.
0020 I/O CHANNEL
Specify a channel for an
input/output device.
I/O CHANNEL
= 0 : Channel 1
= 1 : Channel 1
I/O CHANNEL=0
(channel 1)
0101
Stop bit and other data
0102
Number specified for the
input/output device
0103
Baud rate
I/O CHANNEL=1
(channel 1)
0111
Stop bit and other data
0112
Number specified for the
input/output device
0113
Baud rate
Input/output channel
number (parameter 0020)
Parameter Number
Parameter