OPERATION
7. ALARM AND SELF–DIAGNOSIS
FUNCTIONS
B–63444EN/01
264
Error codes and messages indicate the cause of an alarm. To recover from
an alarm, eliminate the cause and press the reset key.
The error codes are classified as follows:
No. 000 to 232: Program errors(*)
No. 350 and 351: Serial pulse coder (SPC) alarms
No. 400 to 417: Servo alarms
No. 500 to 507: Overtravel alarms
No. 700 to 704: Overheat alarms
No. 900 to 973: System alarms
*For an alarm (No. 000 to 232) that occurs in association with background
operation, the indication “xxxBP/S alarm” is provided (where xxx is an
alarm number). Only a BP/S alarm is provided for No. 140.
See the error code list in the appendix for details of the error codes.
Press the <ALARM> key to toggle back and forth between the alarm
screen and the message screen.
ALARM BAL
100 410
* 402
Alarm screen Message screen
1 Up to four alarms can be displayed at once.
Alarm numbers for the axis type are followed by an axis name.
2 The state of the battery alarm is displayed on the DPL screen the right.
3 The message screen displays external messages from the PMC.
(For details, refer to the manual issued by the machine builder.)
D Reset of the alarm
D Error codes
D
Displaying the Alarm
screen (DPL/MDI)