APPENDIX
B–63444EN/01
G. ALARM LIST
405
Number ContentsMessage
128 ILLEGAL MACRO SEQUENCE
NUMBER
The sequence number specified in the branch command was not 0 to
9999. Or, it cannot be searched. Modify the program.
129 ILLEGAL ARGUMENT ADDRESS An address which is not allowed in <Argument Designation > is used.
Modify the program.
224 RETURN TO REFERENCE POINT Not returned to reference point before cycle start.
231 FORMAT ERROR IN G10 OR L50 Any of the following errors occurred in the specified format at the pro-
grammable–parameter input.
1 Address N or R was not entered.
2 A number not specified for a parameter was entered.
3 The axis number was too large.
4 An axis number was not specified in the axis–type parameter.
5 An axis number was specified in the parameter which is not an
axis type.
6 An attempt was made to reset bit 4 of parameter 3202 (NE9) or
change parameter 3210 (PSSWD) when they are protected by a
password. Correct the program.
233 DEVICE BUSY When an attempt was made to use a unit such as that connected via
the RS–232–C interface, other users were using it.
239 BP/S ALARM While punching was being performed with the function for controlling
external I/O units ,background editing was performed.
240 BP/S ALARM Background editing was performed during MDI operation.
245 T–CODE NOT ALOWED IN THIS
BLOCK
One of the G codes, G50, G10, and G04, which cannot be specified
in the same block as a T code, was specified with a T code.
5010 END OF RECORD The end of record (%) was specified.
2) Background edit alarm
Number Message Contents
070 to 074
085 to 087
BP/S alarm BP/S alarm occurs in the same number as the P/S alarm that occurs
in ordinary program edit.
140 BP/S alarm It was attempted to select or delete in the background a program be-
ing selected in the foreground. (NOTE)
Use background editing correctly.
NOTE
Alarm in background edit is displayed in the key input line of the background edit screen instead
of the ordinary alarm screen and is resettable by any of the MDI key operation.