APPENDIXH. LIST OF OPERATION
B–63444EN/01
410
H
LIST OF OPERATION
(CRT/MDI)
Classifi-
cation
Function
KEY
SW
SETTING
PWE = 1
Mode
Function
key
Operation
Reset
Resetting the OT
alarm
When the
power is on
_
P CANand
Resetting alarm 100 _ _
RESET
CAN
and
Data in-
put from
Inputting parameters f MDI or emer-
gency stop
SYSTEM
(PARAM)
Parameter No. → [NO.SRH] → Data
→ INPUT → PWE = 0 →
INPUT
RESET
the MDI
Inputting offset data f _ OFFSET Offset No. → [NO.SRH] → Offset
value → INPUT
Inputting setting data f MDI SETTING Setting No. → [NO.SRH] → Data →
INPUT
Inputting PMC
parameters (for the
counter and data
table)
f MDI or emer-
gency stop
SYSTEM
(PMC)
[PMCPRM] → [COUNTR] → Data
[DATA]
→
INPUT
Inputting PMC
parameters (for the
timer and keep relay)
f [PMCPRM] → [TIMER] → Data
[KEEPRL]
→
INPUT
Data input
from ex-
ternal I/O
Inputting parameters f EDIT or
emergency
stop
SYSTEM
(PARAM)
[(OPRT)] → [ ] → [READ] → [EXEC]
devices
Inputting PMC
parameters
f Emergency
stop
SYSTEM
(PMC)
[ ] → [I/O]→ (CANNEL NO)
→ (DEVICE NAME) [FDCAS] →
(KIND OF DATA) [PARAM] → [READ] →
(FILE NO) File No . → [EXEC]
1
INPUT
INPUT
Inputting offset data f EDIT OFFSET [(OPRT)] → [ ] → [READ] → [EXEC]
Inputting programs f EDIT PROG [(OPRT)] → [ ] → [READ] → [EXEC]
Data
output to
Outputting
parameters
EDIT SYSTEM
(PARAM)
[(OPRT)] → [ ] → [PUNCH] → [EXEC]
external
I/O
devices
Outputting PMC
parameters
EDIT SYSTEM
(PMC)
[Continuous menu key] → [I/O]→
(CANNEL NO) →
(DEVICE NAME) [FDCAS] → (KIND OF
DATA) [PARAM] → [WRITE] → (FILE NO)
[EXEC]
1
INPUT
–
INPUT
1
Outputting offset data EDIT OFFSET [(OPRT)] → [ ] → [PUNCH] → [EXEC]
Outputting all the
programs
EDIT PROG
→ –9999 → [ ] → [PUNCH] →
[EXEC]
O
Outputting one
program
EDIT PROG
→ Program No. → [ ] → [PUNCH] →
[EXEC]
O