B–63503EN–1/01
4. REFERENCE POSITION ESTABLISHMENT
159
[Valid data range] –99999999 to 99999999
When the butt–type reference position setting function is used, this
parameter sets a distance an axis, along which withdrawal is performed
after the mechanical stopper is hit (distance from the mechanical stopper
to the withdrawal point).
NOTE
Set the same direction as the direction set for ZMIx, bit 5 of
parameter No. 1006. If the opposite direction is set, the
cycle operation will not start.
7182 Second withdrawal distance in butt–type reference position setting
[Data type] 2–word axis
Increment system IS–B IS–C Unit
Millimeter machine 0.001 0.0001 mm
Inch machine 0.0001 0.00001 inch
[Valid data range] –99999999 to 99999999
When the butt–type reference position setting function is used, this
parameter sets a distance an axis, along which withdrawal is performed
after the mechanical stopper is hit (distance from the mechanical stopper
to the withdrawal point).
NOTE
Set the same direction as the direction set for ZMIx, bit 5 of
parameter No. 1006. If the opposite direction is set, the
cycle operation will not start.
7183 First butting feedrate in butt–type reference position setting
[Data type] Word axis
Valid data range
Increment system Unit of data
IS–B IS–C
Millimeter machine 1 mm/min 30–15000 30–12000
Inch machine 0.1 inch/min 30–6000 30–4800
When the butt–type reference position setting function is used, this
parameter sets the feedrate first used to hit the stopper on an axis.
7184 Second butting feedrate in butt–type reference position setting
[Data type] Word axis
Valid data range
Increment system Unit of data
IS–B IS–C
Millimeter machine 1 mm/min 30–15000 30–12000
Inch machine 0.1 inch/min 30–6000 30–4800
[Unit of data]
[Unit of data]
[Valid data range]
[Unit of data]
[Valid data range]