B–63503EN–1/01
11. PROGRAM COMMAND
561
Number Message Description
076 ADDRESS P NOT
DEFINED
Address P (program number) was not com-
manded in the block which includes an
M98, G65, or G66 command. Modify the
program.
077 SUB PROGRAM
NESTING ERROR
The subprogram was called in five folds.
Modify the program.
078 NUMBER NOT FOUND A program number or a sequence number
which was specified by address P in the
block which includes an M98, M99, M65 or
G66 was not found. The sequence number
specified by a GOTO statement was not
found. Otherwise, a called program is being
edited in background processing. Correct
the program, or discontinue the back-
ground editing.
110 DATA OVERFLOW The absolute value of fixed decimal point
display data exceeds the allowable range.
Modify the program.
111 CALCULATED DATA
OVERFLOW
The result of calculation is out of the allow-
able range (–10
47
to –10
–29
, 0, and 10
–29
to 10
47
).
112 DIVIDED BY ZERO Division by zero was specified. (including
tan 90_)
113 IMPROPER COMMAND A function which cannot be used in custom
macro is commanded.
Modify the program.
114 FORMAT ERROR IN
MACRO
There is an error in other formats than <For-
mula>.
Modify the program.
115 ILLEGAL VARIABLE
NUMBER
A value not defined as a variable number is
designated in the custom macro.
Modify the program.
116 WRITE PROTECTED
VARIABLE
The left side of substitution statement is a
variable whose substitution is inhibited.
Modify the program.
118 PARENTHESIS NESTING
ERROR
The nesting of bracket exceeds the upper
limit (quintuple).
Modify the program.
119 ILLEGAL ARGUMENT The SQRT argument is negative, BCD ar-
gument is negative, or other values than 0
to 9 are present on each line of BIN argu-
ment.
Modify the program.
122 DUPLICATE MACRO
MODAL–CALL
The macro modal call is specified in double.
Modify the program.
123 CAN NOT USE MACRO
COMMAND IN DNC
Macro control command is used during
DNC operation.
Modify the program.
124 MISSING END
STATEMENT
DO – END does not correspond to 1 : 1.
Modify the program.
Alarm and message