B–63503EN–1/01
11. PROGRAM COMMAND
607
[Data type] Bit
SPK Specifies whether to use small–hole peck drilling cycle, as follows :
0 : Not to use.
1 : Use.
NOTE
It is impossible to select the small–hole peck drilling cycle
and scaling functions at the same time.
#7 #6 #5 #4 #3 #2 #1 #0
5160 NOL OLS
[Data type] Bit
OLS When an overload torque signal is received in a peck drilling cycle of a
small diameter, the feed and spindle speed are
0 : Not changed.
1 : Changed.
NOL When the depth of cut per action is satisfied although no overload torque
signal is received in a peck drilling cycle of a small diameter, the feed and
spindle speed are:
0 : Not changed.
1 : Changed.
5163 M code that specifies the peck drilling cycle mode of a small diameter
[Data type] Two–word
[Unit of data]
[Valid data range] 1 to 99999999
This parameter sets an M code that specifies the peck drilling cycle mode
of a small diameter.
5164 Percentage of the spindle speed to be changed when the tool is retracted after an
overload torque signal is received
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 255
This parameter sets the percentage of the spindle speed to be changed
when the tool is retracted because the overload torque signal is received in
a peck drilling cycle of a small diameter.
S2 = S1 d1 B 100
S1: Spindle speed to be chaged
S2: Spindle speed changed
d1 is set as a percentage.