B–63503EN–1/01
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
268
#7
8131
#6 #5 #4 #3 #2
EDC
#1 #0
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Bit
EDC Specifies whether to use external deceleration, as follows :
0 : Not to use.
1 : Use.
#7
1005
#6 #5
EDMx
#4
EDPx
#3 #2 #1 #0
[Data type] Bit axis
EDPx External deceleration signal in the positive direction for each axis
0 : Valid only for rapid traverse
1 : Valid for rapid traverse and cutting feed
EDMx External deceleration signal in the negative direction for each axis
0 : Valid only for rapid traverse
1 : Valid for rapid traverse and cutting feed
1426 External deceleration rate of cutting feed
[Data type] Word
Valid data range
y
IS-B IS-C
Millimeter machine 1 mm/min 6 – 15000 6 – 12000
Inch machine 0.1 inch/min 6 – 6000 6 – 4800
Set the external deceleration rate of cutting feed.
1427 External deceleration rate of rapid traverse for each axis
[Data type] Word axis
Valid data range
y
IS-B IS-C
Millimeter machine 1 mm/min 6 – 15000 6 – 12000
Inch machine 0.1 inch/min 6 – 6000 6 – 4800
Rotation axis 1 deg/min 6 – 15000 6 – 12000
Set the external deceleration rate of rapid traverse for each axis.
Parameter
[Unit of data]
[Valid data range]
[Unit of data]