B–63503EN–1/01
12. DISPLAY/SET/EDIT
627
NOTE
When bit 0 (PCM) of parameter No. 6700 is set to 1, the
number of parts is not counted with M02 and M30.
6713 Number of required parts
Setting entry is acceptable.
[Data type] Word
[Unit of data] One piece
[Valid data range] 0 to 9999
This parameter sets the number of required machined parts.
Required parts finish signal PRTSF is output to PMC when the number
of machined parts reaches the number of required parts. The number of
parts is regarded as infinity when the number of required parts is zero. The
PRTSF signal is then not output.
6750 Integrated value of power–on period
Setting entry is acceptable.
[Data type] Two–word
[Unit of data] One min
[Valid data range] 0 to 99999999
This parameter displays the integrated value of power–on period.
6751 Operation time (integrated value of time during automatic operation)
Setting entry is acceptable.
[Data type] Two–word
[Unit of data] One ms
[Valid data range] 0 to 60000
6752 Operation time (integrated value of time during automatic operation)
Setting entry is acceptable.
[Data type] Two–word
[Unit of data] One min
[Valid data range] 0 to 99999999
This parameter displays the integrated value of time during automatic
operation (neither stop nor hold time included).
The actual operation time is the sum of the values set in parameter Nos.
6751 and 6752.