5. AUTOMATIC OPERATION
175
[Classification] Input signal
[Function] Enables dry run.
[Operation] When this signal is set to 1, the tool is moved at the feedrate specified for
dry run.
When this signal is set to 0, the tool is moved normally.
CAUTION
When the dry run signal is changed from 0 to 1 or 1 to 0
during the movement of the tool, the feedrate of the tool is
first decelerated to 0 before being accelerated to the
specified feedrate.
[Classification] Output signal
[Function] Notifies the PMC of the state of the dry run signal.
[Output condition] This signal is set to 1 in the following case:
– When dry run signal DRN is set to 1
This signal is set to 0 in the following case:
– When dry run signal DRN is set to 0
#7 #6 #5 #4 #3 #2 #1 #0
G046
F002
DRN
MDRN
Signal
Dry run signal
DRN <G046#7>
Dry run check signal
MDRN <F002#7>
Signal address