
5. AUTOMATIC OPERATION
B–63503EN–1/01
198
#7 #6 #5 #4 #3 #2 #1 #0
G062 RTNT
#7 #6 #5 #4 #3 #2 #1 #0
F066 RTPT
#7 #6 #5 #4 #3 #2 #1 #0
5200 DOV
[Data type] Bit
DOV For tool extraction during rigid tapping, override is:
0 : Disabled.
1 : Enabled.
5381 Override for rigid tapping retraction
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 200
Sets an override value to be applied to rigid tapping retraction. No
override is applied if 0 is set.
NOTE
This parameter is enabled only when the parameter used to
enable tool extraction (DOV: bit 4 of No. 5200) is set to 1.
5382 Retract value α for rigid tapping return
[Data type] 2–word
[Unit of data] Input increments
[Valid data range] 0 to 99999999
Sets an extra retract value for rigid tapping retraction. The tool will be
pulled beyond the R point by α. If rigid tapping retraction has already
been completed, the tool is pulled by α only.
Signal address
Parameter