8. AUXILIARY FUNCTION
B–63503EN–1/01
332
#7
G004
#6 #5 #4 #3
FIN
#2 #1 #0
F001 DEN
#7 #6 #5 #4 #3 #2 #1 #0
BFF007 BF TF SF MF
DM00F009 DM01 DM02 DM30
M07F010 M06 M05 M04 M03 M02 M01 M00
M15F011 M14 M13 M12 M11 M10 M09 M08
M23F012 M22 M21 M20 M19 M18 M17 M16
M31F013 M30 M29 M28 M27 M26 M25 M24
S07F022 S06 S05 S04 S03 S02 S01 S00
S15F023 S14 S13 S12 S11 S10 S09 S08
S23F024 S22 S21 S20 S19 S18 S17 S16
S31F025 S30 S29 S28 S27 S26 S25 S24
T07F026 T06 T05 T04 T03 T02 T01 T00
T15F027 T14 T13 T12 T11 T10 T09 T08
T23F028 T22 T21 T20 T19 T18 T17 T16
T31F029 T30 T29 T28 T27 T26 T25 T24
B07F030 B06 B05 B04 B03 B02 B01 B00
B15F031 B14 B13 B12 B11 B10 B09 B08
B23F032 B22 B21 B20 B19 B18 B17 B16
B31F033 B30 B29 B28 B27 B26 B25 B24
#7
8132
#6 #5 #4 #3 #2
BCD
#1 #0
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Bit
BCD Specifies whether to use the 2nd auxiliary function, as follows :
0 : Not to use.
1 : Use.
Signal address
Parameter