B–63503EN–1/01
10. TOOL FUNCTIONS
529
[Classification] Input signal
[Function] When the TLRST or TLSKP signals are input, the tool group number
must be given in advance, using the tool group number selection signals
TL01 to TL16 (T series) or TL01 to TL128 (M series).
Command the following value in binary form:
Tool group number to be specified –1
[Operation] A specified tool group is selected.
[Classification] Input signal
[Function] Overrides the life count (time) if parameter LFV (No. 6801#2) is
specified.
Each of the ten binary code signals has a unique override value that
becomes valid when the signal is set to “0”. The life count is overridden
by the sum of the valid override values. The override value can be
specified in steps of 0.1, within the range of 0 to 99.9.
Override value =
ȍ
9
i+0
{2
i
Vi}
*TLV0 0.1
*TLV1 0.2
*TLV2 0.4
*TLV3 0.8
*TLV4 1.6
*TLV5 3.2
*TLV6 6.4
*TLV7 12.8
*TLV8 25.6
*TLV9 51.2
(Example) When *TLV7, *TLV6, and *TLV3 are set to “0”, the override
value is calculated as follows:
12.8 + 6.4 + 0.8 = 20.0
The life count is multiplied by 20.0.
[Operation] The actual cutting time is counted and multiplied by the override value
obtained by the signals. The calculated time is used as the basis for
tool-life management.
Tool group number
select signal
TL01 to TL128 (M series)
<G047#0 to #7>
TL01 to TL 16
<G47#0 to #4> (T series)
Tool life count override
signal *TLV0 to *TLV9
<G049#0 to G050#1>
(M series)