8. SAFETY ZONE CHECK
B–63683EN/01
148
#7
YSF16500
#6 #5
SAT
#4 #3 #2 #1 #0
SF0
[Data type] Bit
SF0 The safety zone of type:
0 : A is used.
1 : B is used.
SAT When punching is inhibited in the safety zone, the block in which a T
command is specified is checked:
0 : In advance.
1 : After the FIN signal to complete the T command has been received.
YSF When a safety zone check is executed, the inhibited area along the Y axis
extends from the values set in parameters 16507, 16510, 16513, and
16516:
0 : In the negative direction.
1 : In the positive direction.
#7
16501
#6 #5 #4 #3
SZ4
#2
SZ3
#1
SZ2
#0
SZ1
[Data type] Bit
SZj When a safety zone check is executed, in the #j (j = 1 to 4) area,
0 : An entry is inhibited.
1 : Punching is inhibited.
#7
SOF16502
#6 #5 #4
SZI
#3
GSZ
#2
ZIO
#1
SZC
#0
MDP
[Data type] Bit
MDP On the safety zone setting display,
0 : The workpiece coordinate system is indicated.
1 : The machine coordinate system is indicated.
SZC On the safety zone setting display, the data for:
0 : Any zone can be changed.
1 : Those zones to be set automatically (parameter 16534) can be
changed.
ZIO When the safety zone is automatically set by an external signal, the
position of a workpiece holder is detected according to:
0 : The on and off states of the SAFZ signal used to detect the position of
a workpiece holder.
1 : The on state of the SAFZ signal used to detect the position of a
workpiece holder.
GSZ On the graphic screen, the safety zone is checked according to the position
of a workpiece holder:
0 : Specified on the safety zone screen.
1 : Specified by graphic parameters.
(On the graphic screen, this check is executed in an area that is not
related to the actual machining check.)
8.7
PARAMETER