B–63683EN/01
2. FUNCTION SPECIFICATIONS THAT DIFFER
FROM THE M series
15
CAUTION
When the T–axis control function is used, the servo–off
signal is generally used for a shot pin after T–axis
positioning. If the *FLWU signal is set to 0, the follow–up
function operates and sets the T–axis machine position
signal and turret indexing completion signal to 0. If this
occurs, turret indexing by a subsequent T command will
result in incorrect positioning.
When turning the servo–off signal on or off during T–axis
control or automatic operation, set the *FLWU signal to 1 in
advance.
The rotary axis roll over function cannot be used together with T–axis or
C–axis control.
1. Simple synchronous control can be turned on or off during automatic
operation. After simple synchronous control is turned off, the absolute
command (G90) must be first specified for the axis which was used as
the slave axis. If the incremental command (G91) is specified, correct
operation cannot be performed.
2. When using the high–speed press control function, the simple
synchronous control function cannot be used for multiple pairs of
axes.
2.1.5
Follow–up
2.1.6
Rotary Axis Roll Over
Difference
2.1.7
Simple Synchronous
Control
Difference