2. FUNCTION SPECIFICATIONS THAT DIFFER
FROM THE M series
B–63683EN/01
28
16878 Positioning time for level 1 (when rapid traverse override is 100% or 75%)
16879 Positioning time for level 2 (when rapid traverse override is 100% or 75%)
16880 Positioning time for level 1 (when rapid traverse override is 50% or 25%)
16881 Positioning time for level 2 (when rapid traverse override is 50% or 25%)
[Data type] Byte axis
[Unit of data] ms
[Valid data range] 8 to 248
When using constant positioning time control, set the positioning time for
levels 1 and 2, for each axis.
These parameters are valid for those axes for which both bits 7 (KL2j) and
6 (PT2j) of parameter No. 16844 are set to 1.
16882 Position gain for level 1
16883 Position gain for level 2
16884 Position gain for level 3
16885 Position gain for level 4
16886 Position gain for level 5
16887 Position gain for level 6
16888 Position gain for level 7
[Data type] Word axis
[Unit of data] 0.01 s
–1
[Valid data range] 1 to 9999
Set the positioning control servo loop gain corresponding to each
positioning distance, for each axis.
These parameters are valid for those axes for which both bits 7 (KL2j) and
4 (LP2j) of parameter No. 16844 are set to 1.
16160 Servo loop gain for cutting feed
[Data type] Word axis
[Unit of data] 0.01 s
–1
[Valid data range] 1 to 9999
Set the positioning control servo loop gain to be applied during cutting
feed, for each axis.
This parameter is valid when bit 7 (PGC) of parameter No. 16051 is set to
1.