2. FUNCTION SPECIFICATIONS THAT DIFFER
FROM THE M series
B–63683EN/01
16
If the end point specified for rapid traverse positioning that constitutes
part of an automatic operation falls outside a predetermined range, no
axial movements are made. Instead, an alarm is output. (Stroke check
before travel)
Number Message Contents
4700 PROGRAM ERROR (OT+) The value specified in the X–axis
move command exceeded the posi-
tive value of stored stroke limit 1.
(Advance check)
4701 PROGRAM ERROR (OT–) The value specified in the X–axis
move command exceeded the nega-
tive value of stored stroke limit 1.
(Advance check)
4702 PROGRAM ERROR (OT+) The value specified in the Y–axis
move command exceeded the posi-
tive value of stored stroke limit 1.
(Advance check)
4703 PROGRAM ERROR (OT–) The value specified in the Y–axis
move command exceeded the nega-
tive value of stored stroke limit 1.
(Advance check)
2.2
PREPARATIONS FOR
OPERATION
2.2.1
Stored Stroke Limit 1
Difference
Alarm and message