B-63944EN-1/02 OPERATION 2.SETTING AND DISPLAYING DATA
- 369 -
X
Z
X’
Z’
O
O’
Shift
Fig. 2.1.5 (b)
Explanation
- When shift values become valid
Shift values become valid immediately after they are set.
- Shift values and coordinate system setting command
Setting a command (G50 or G92) for setting a coordinate system
disables the set shift values.
Example)
When G50 X100.0 Z80.0; is specified, the coordinate system is
set so that the current tool reference position is X+100.0, Z+80.0
regardless of the shift values.
- Shift values and coordinate system setting
If the automatic coordinate system setting is performed by manual
reference position return after shift amount setting, the coordinate
system is shifted instantly.
- Diameter or radius value
Whether the shift amount on the X-axis is diameter or radius value
depends on that specified in program.
- Position record signal
When bit 2 (PRC) of parameter No. 5005 is 1, the absolute
coordinates when the position record signal is ON are recorded for
calculation of the shift amount.
Example
When the actual position of the reference point is X=121.0 (diameter),
Z=69.0 with respect to the workpiece origin but it should be X=120.0,
Z=70.0, set the following shift values:
X=1.0, Z=-1.0